VEKSLER INSTRUMENTS
Glass Tube Rotameter
Home
Company Profile
Inquiry
Contact Us
Magnetic Level Indicator
Reflex & Transparent Level Gauges
Reflex Level Gauge
Click to Enlarge
Reflex Level Gauge (RLG-19)
Reflex Level Gauge is designed for measurement of liquid level in vessels under high pressure & temperature conditions. It is a flat glass gauge, which has precision Mounded prismatic grooves cut on its inner side coming in contact with the medium. Light striking the glass covered by liquid is refracted (absorbed) into the liquid making this portion appear black, whereas light covering the vapor space is reflected back towards the viewers, making it appear silvery-white. Thus, a sharp clear line marks the liquid, eliminating all possibilities of errors in reading.
 
Technicals
  • Designed for liquid level indication in vessels under high pressure & Temperature conditions.
  • PP, CS, MS, SS 304, SS 316, SS 316L Chambers and isolation valves.
  • Chamber machined from 40 mm square bar with 1/2" BSP drain & Vent plugs.
  • Tempered borosilicate glass (Indigeneour/Klingerite), resistant to chemicals, thermal & mechanical shocks.
  • Working pressure 65 kg/cm2 max and 4500 C temperature.
  • Graded Alloy Steel U Bolts, Nuts and Studs as std and SS on demand.
  • Flanged connection drilled to ASA 150# or as per customer's requirement.
  • Choice of medium and high pressure designs in various body & gaskets materials to suit process media and temperature.
  • Trouble – free operation, except for occasional cleaning.
  • Large chamber construction available for boiling, foaming, flashing or surging liquids.
  • Weld – Pad construction available for liquids containing suspended solids, or for situations, where piping is not acceptable or space is a limiting factor.
  • Isolating valves, safety ball check, scale, illuminator, frost free, heating/cooling arrangement are optional.
  • Variety of accessories & special features like isolating valves, safety ball check, scale illuminator, frost free heating/ cooling arrangements.
Transparent Level Gauge (TPLG-19)
Transparent Level Gauge is designed for measurement of liquid level in tanks under high pressure and temperature conditions. It consists of double flat glass mounted opposite to each other on a chamber. The glasses are held together by studs through cover plates. It is used for interface services or when the process is dirty or viscous. The chamber is available in a variety of metallurgy i.e. PP, CS, MS, SS304, SS316, SS 316L etc. The isolation valves can also be supplied in different metallurgy depending upon process fluid.
 
Features
  • Tempered borosilicate glass, resistant to chemicals, thermal & mechanical shocks
  • Choice of medium and high pressure designs is available in various body & gaskets materials to suit process conditions.
  • Trouble – free operation, but requires occasional cleaning.
  • Large chamber construction available for boiling, foaming, flashing or surging liquids.
  • Weld – Pad construction is also available for liquids containing suspended solids, or for location where piping is not acceptable or space is limited.
  • Internal Mica/ Plastic Shields for glass protection from services like caustic, hydrofluoric acid & steam drums above 250 psig.
  • Accessories & special features like isolating valves, safety ball check, scale, illuminator, frost free, heating/ cooling arrangements are available.
Specifications
Construction Standard/Large chamber or weld pad
Glass Plates

Tempered borosilicate (indigenous or klinger) in 30 mm width as Standard

Sealing Gasket/cushion CAF, PTFE (Indigenous) or Klingerite
Body MS, CS, SS304, SS316, PP as standard
Cover Plate MS, CS, SS304, SS316, PP as standard
Bolts/ Nuts MS or Graded Alloy steel for high temperature.
C/C Distance 1600 mm in single length. Extended ranges through a Coupler
Chamber Entry Top or side/ Rear
Connection Flanged, Screwed with vertical or horizontal orientation
Vent/ Drain ½" plug (BSP/NPT)
Drain Valve ½" Needle/Ball/Diaphragm Type if required
Max. Pressure 0-30 Kg/cm² (Indigenous glass), 0-65 (Klinger glass)
Max. Temperature 0-300ºC (Indigenous glass), 0-400 (Klinger glass)
Scale Al/SS scale calibrated for level values in mm/inches With LC 5 mm as standard or 1 mm on request.
 
A SITE CONDITIONS  
01 Ambient Temperature (Max/Min)  
02 Relative Humidity  
03 General Climate  
B PROCESS CONDITIONS  
01 Fluid Liquid
02 Normal/Max Pressure (Design Pressure) Please specify
03 Temperature / Design Temp.) 150 Deg C/350 Deg C
04 Density of Fluid -
C TECHNICAL PARTICULARS  
01 Type  
02 Indication Local on tank side
03 Mounting Side - Side
04 C.C. Distance  
05 Scale Width 25 mm
06 Scale Graduations In mm
07 Minimum Graduations 5 mm
08 Letter Height 10 mm
09 Process Connection  
10 Deg of Prot of Enclosure Not applicable
11 Max. Working Temperature  
12 Max Working  Pressure 10 Kg/cm2
13 Hydraulic Test Pressure  
14 Vent & Drain Connection ½” BSP plug  
D MATERIAL OF CONST  
01 Main Body Machined from 40 x 40 mm square bar
02 Cover Plate MOC CS/SS 304/PP
03 Flanges  
04 Packing  
05 Hardware Borosilicate Glass,19 mm OD
06 Reflex Glass Toughened Borosilicate with reflex grooves
07 Scale Anodized Alluminium
08 Finish Mat Finish
09 Finish Shade Black for Cover Plates
10 Accessories  
11 Tag Plate Provided
E MANUFACTURER’S DETAILS  
01 Manufacturer Veksler
02 Model No  
03 Product Catalogue  
Back to Top